TEF Fire Detection

tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 EN54‑2 and EN54‑4 CERTIFIED 1328‑CPR‑0160 ORDER CODE TECHNICAL SPECIFICATIONS ORION Key Features 2, 4 and 8 Zone non‑expandable control panels Up to 32 conventional smoke and/or heat detectors per Zone Active End of Line monitoring Programmable non‑latching Zones Delay timer programmable on/off per Zone Coincidence programmable for adjacent Zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset 2 Relay outputs fire and fault Fully EN54 part 2 and 4 compliant Repeater output Multiplexed output for LEDs and additional relay outputs per zone (GFE‑MPX‑REL) Multiplexed output for sounders per zone (GFE‑MPX‑SNDR) Addressable Loop Interface card (GFE‑ADLI) 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL ORION 2 ORION 4 ORION 8 230 +10% -15% V AC 28.5 V DC nominal 1.7 A @ 28.5 V DC nominal (max.) 21.0 min. - 27.2 max. V DC - BAT charger o/p 28 V DC 0 1.1 Amp Maximum @ 20 C 2 x 12V x 7Ah Sealed VRLA Lead Acid Batteries 4 A -250 V Slow Blow - 20 mm 1.6 Amp - Resettable 2,4 or 8 4 mA / 60 mA - Maximum 40 Ohms / 0.470 uF Active EOL - 10uF/50V Bipolar Electrolytic Aluminium Capacitor YES provided diodes are fitted to detector base 32 Maximum - EN54 pt.2 270 - 1000 Ohms 2 outputs w/ 500mA max. current drive per circuit - fully monitored 27.5 V DC Nominal / 10 K Ohms - 1/4 Watt 1 Fire (COM-NC-NO) - 1 Fault (COM-NC) non-supervised 50 V DC - 1 Amp resistive loads Non-Latching - Voltage free contact Non-Latching - Voltage free contact Max 95% RH Non-Condensing IP30 -10ºC to 50ºC 1.7 Kg - 7 Kg (inc. 2 x 7 AH 12 V bat.) 273 (L) x 107 (W) x 404 (H) mm White or Red SUPPLY SPECIFICATION PRIMARY SUPPLY VOLTAGE - IN PRIMARY SUPPLY VOLTAGE - OUT PRIMARY SUPPLY CURRENT - OUT SECONDARY SUPPLY VOLTAGE SECONDARY SUPPLY CURRENT OUTPUT INTERNAL BATTERY CAPACITY - MAXIMUM MAINS FUSE BATTERY FUSE DETECTION CIRCUIT SPECIFICATION NUMBER OF CIRCUITS ZONE CURRENT - QUIESCENT / ALARM MAX. CABLE RESISTANCE / CAPACITANCE END OF LINE MONITORING BS-5839 DETECTOR REMOVAL COMPLIANT DEVICES PER ZONE ALARM RESISTANCE VALUE SOUNDER CIRCUIT SPECIFICATION CURRENT OUTPUT ALARM VOLTAGE / END OF LINE RESISTOR AUXILIARY OUTPUTS SPECIFICATION AUXILIARY RELAY OUTPUT RELAY CONTACT RATING REMOTE INPUT SPECIFICATION EVACUATION (CC) - DAY/ NIGHT MODE RESET MECHANICAL & OPERATING SPEC. HUMIDITY PROTECTION OPERATING TEMPERATURE WEIGHT DIMENSIONS COLOUR 1328-CPR-0224 1328-CPR-0224 1328-CPR-0224

RkJQdWJsaXNoZXIy MTY2MjU=