tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 MANUFACTURERS OF FIRE DETECTION EQUIPMENT PRODUCTS CATALOGUE
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 Building on a long tradition of excellence in the field of Fire Alarm Control Panels, Global Fire Equipment S.A., founded in Denmark by João Paulo Ajami, has experienced a remarkable organic growth both in turnover and customer numbers since 1994 and is now a world player, supplying customers across 75 countries with state of the art equipment, installed in prestige premises ranging from major airports to an Antarctic research base. Based in a modern logistics center in the Algarve region of Portugal, GFE designs, manufactures and exports a complete range of Fire Detection Products and puts customer satisfaction at the top of its priorities. THE WAY WE LEAD
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 PANELS DETECTORS MANUAL CALL POINTS SOUNDERS & BEACONS MODULES INTERFACES DOOR HOLDERS POWER SUPPLY UNITS SOFTWARE ADDRESSABLE SYSTEM OVERVIEW 4 25 40 45 66 85 97 100 105 112
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 PANELS
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 EN54‑2 and EN54‑4 CERTIFIED 1328‑CPR‑0160 The ORION conventional control panel range offers a creatively designed and visually pleasing solution for smaller cost‑ conscious projects demanding simplicity of operation. Versions available include 2, 4 and 8 zone panels and two styles of repeater. The outstanding programmable features included in this panel range contradict the facilities commonly available in this type of panel and include꞉ programmable time delay by zone, Day/Night mode, selectable non‑latching zones and coincidence detection. Operation is extremely intuitive, offering simple control and one‑button disablement facilities, as well as the one man test mode which provides simple and efficient testing of the system. Advanced configuration solutions include the following꞉ a dedicated RS232 communication interface allowing connection of up to 4 remote repeater panels, addressable loop interface modules and multiplexed zonal output relays; giving one of the most highly advanced levels of system integration and compatibility existing on the market at this level. KEY FEATURES ● 1 to 4 loops panel ● Networkable panel, compatible with OCTO+ and NODE+ range of panels ● Supports connection to Repeaters via RS422, Fibre‑Optic or TCP/IP ● 250 devices per loop (125 address limit) ● Up to 95 VULCAN 2 (addressable) ultra low current base sounders (32 address limit) ● 32 individually programmable sounder addresses ● Full Self‑Addressable Devices support ● 2 Fire output relays (change‑over) and 1 Fault relay (NC ‑ opens on fault) ● 2 conventional alarm outputs (individually programmable) ● Both detection loops monitored for integrity ● 384 fully programmable zones ● 512 fully programmable sounder groups ● 512 I/O groups ● Event log (rolling, 10000 entries) ● Available only with ZEOS protocol ● Compatible with all our own low cost ancillary modules ● Backlit graphical LCD display of 240x64 pixels ● Programming by integrated keypad or Loader PC software ● Multiple language support (menu selectable) ● Integrated 16 zone LED fire zone indication ORION Conventional Fire Detection System
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 EN54‑2 and EN54‑4 CERTIFIED 1328‑CPR‑0160 ORDER CODE TECHNICAL SPECIFICATIONS ORION Key Features 2, 4 and 8 Zone non‑expandable control panels Up to 32 conventional smoke and/or heat detectors per Zone Active End of Line monitoring Programmable non‑latching Zones Delay timer programmable on/off per Zone Coincidence programmable for adjacent Zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset 2 Relay outputs fire and fault Fully EN54 part 2 and 4 compliant Repeater output Multiplexed output for LEDs and additional relay outputs per zone (GFE‑MPX‑REL) Multiplexed output for sounders per zone (GFE‑MPX‑SNDR) Addressable Loop Interface card (GFE‑ADLI) 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL ORION 2 ORION 4 ORION 8 230 +10% -15% V AC 28.5 V DC nominal 1.7 A @ 28.5 V DC nominal (max.) 21.0 min. - 27.2 max. V DC - BAT charger o/p 28 V DC 0 1.1 Amp Maximum @ 20 C 2 x 12V x 7Ah Sealed VRLA Lead Acid Batteries 4 A -250 V Slow Blow - 20 mm 1.6 Amp - Resettable 2,4 or 8 4 mA / 60 mA - Maximum 40 Ohms / 0.470 uF Active EOL - 10uF/50V Bipolar Electrolytic Aluminium Capacitor YES provided diodes are fitted to detector base 32 Maximum - EN54 pt.2 270 - 1000 Ohms 2 outputs w/ 500mA max. current drive per circuit - fully monitored 27.5 V DC Nominal / 10 K Ohms - 1/4 Watt 1 Fire (COM-NC-NO) - 1 Fault (COM-NC) non-supervised 50 V DC - 1 Amp resistive loads Non-Latching - Voltage free contact Non-Latching - Voltage free contact Max 95% RH Non-Condensing IP30 -10ºC to 50ºC 1.7 Kg - 7 Kg (inc. 2 x 7 AH 12 V bat.) 273 (L) x 107 (W) x 404 (H) mm White or Red SUPPLY SPECIFICATION PRIMARY SUPPLY VOLTAGE - IN PRIMARY SUPPLY VOLTAGE - OUT PRIMARY SUPPLY CURRENT - OUT SECONDARY SUPPLY VOLTAGE SECONDARY SUPPLY CURRENT OUTPUT INTERNAL BATTERY CAPACITY - MAXIMUM MAINS FUSE BATTERY FUSE DETECTION CIRCUIT SPECIFICATION NUMBER OF CIRCUITS ZONE CURRENT - QUIESCENT / ALARM MAX. CABLE RESISTANCE / CAPACITANCE END OF LINE MONITORING BS-5839 DETECTOR REMOVAL COMPLIANT DEVICES PER ZONE ALARM RESISTANCE VALUE SOUNDER CIRCUIT SPECIFICATION CURRENT OUTPUT ALARM VOLTAGE / END OF LINE RESISTOR AUXILIARY OUTPUTS SPECIFICATION AUXILIARY RELAY OUTPUT RELAY CONTACT RATING REMOTE INPUT SPECIFICATION EVACUATION (CC) - DAY/ NIGHT MODE RESET MECHANICAL & OPERATING SPEC. HUMIDITY PROTECTION OPERATING TEMPERATURE WEIGHT DIMENSIONS COLOUR 1328-CPR-0224 1328-CPR-0224 1328-CPR-0224
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 EN54‑2 and EN54‑4 CERTIFIED 1328‑CPR‑0160 ORDER CODE TECHNICAL SPECIFICATIONS CONVENTIONAL MINI-REPEATER PANEL - INCLUDES 1 X RS232 INTERFACE 28 V DC nominal derived from Orion Aux. Supply O/P 40 mA +Supply, -Supply, TX and RX RS232, RS485, FO or TCP/IP - 1 Display & Control 3 Display Only 95% RH Non-Condensing -10ºC to 50ºC 1.4 Kg 194 (L) x 256 (W) x 75 (H) mm White or Red SUPPLY VOLTAGE SUPPLY CURRENT CONNECTIONS REPEATER NETWORK MAX. HUMIDITY OPERATING TEMPERATURE WEIGHT DIMENSIONS COLOUR ORION MINI-REP ORION MINI‑REP Orion Mini‑Repeater Panel The ORION MINI‑REP will provide remote control, system status display and monitoring functions. All Fire, Fault, Test and Disabled conditions are displayed. User is able to control all functions at access Level’s 1 and 2. Compliant with EN54‑2. Display and Control Functions are replicated and shown in the same manner as on the ORION Fire Detection Panel. Access to Level 2 is via a four digit code (same code as used on the ORION Conventional Panel). It includes as standard an RS232 interface. This unit is also compatible with all of GFE’s standard data loop interfaces, allowing the ORION MINI‑REP panel to be interfaced to an ORION Conventional Panel using 4 different interfacing technologies꞉ RS232 RS485 Fibre Optics TCP/IP (specific for ORION Conventional Systems) A maximum of 4 ORION MINI‑REP panels can be connected to a single ORION Conventional Fire Detection Panel. When using data loop interfaces, only one repeater panel will offer both control and display of the system. The remainder of the repeater panels will only offer system status display. This unit is available in both white and red colours.
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 EN54‑2 and EN54‑4 CERTIFIED 1328‑CPR‑0160 The GEKKO Fire Alarm Control Panel is the successor of the enormously popular GFE JUNIOR panel. The GEKKO can have from 1 to 4 addressable loops. It is housed in a functional ABS plastic enclosure, with only two screws used to close and secure the lid. The new graphic backlit LCD display can accommodate any type of custom characters or graphic symbols, allowing multi‑language support, as well as pictorial and customisable elements. It can naturally also communicate with our proprietary ODYSSEY Graphics Interface, as well as with third party Building Management Systems through a Modbus output. It is also capable to communicate with a Repeater unit, using any of the networking interfaces of the CHAMELEON protocol. Inside the cabinet there is space for installing up to 7 A/H 24 V DC Sealed Lead Acid backup batteries, providing battery supply to the GEKKO and ZEOS associated devices, which boast extremely low current consumption. The Cause and Effect programming, as well as all customer specific configuration, is introduced in the GEKKO using the CHAMELEON CONNECTOR software which is then downloaded to the Flash Memory of the unit. KEY FEATURES ● 1 to 4 loops panel ● Networkable panel, compatible with OCTO+ and NODE+ range of panels ● Supports connection to Repeaters via RS422, Fibre‑Optic or TCP/IP ● 250 devices per loop (125 address limit) ● Up to 95 VULCAN 2 (addressable) ultra low current base sounders (32 address limit) ● 32 individually programmable sounder addresses ● Full Self‑Addressable Devices support ● 2 Fire output relays (change‑over) and 1 Fault relay (NC ‑ opens on fault) ● 2 conventional alarm outputs (individually programmable) ● Both detection loops monitored for integrity ● 384 fully programmable zones ● 512 fully programmable sounder groups ● 512 I/O groups ● Event log (rolling, 10000 entries) ● Available only with ZEOS protocol ● Compatible with all our own low cost ancillary modules
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 TECHNICAL SPECIFICATIONS POWER SUPPLY RATING 90V AC to 220V AC @ 65 W PRIMARY SUPPLY 28.5V DC @ 2.4 A (Max.) SECONDARY SUPPLY 21.7V DC to 27.2V DC; BAT charger꞉ 28V DC BATTERIES (INTERNAL) 2 x 12 V 7 AH QUIESCENT CURRENT (NO DEVICES) 65 mA (4 Loop) AUX. POWER OUTPUT 28V DC 300 mA LOOPS 1 to 4 loops ‑ Max 150 mA per loop CONVENTIONAL SOUNDER CIRCUITS 2 ‑ 500 mA Max. current drive per circuit ‑ Fully monitored AUX. RELAYS FIRE 2 rated 2A @ 30V DC resistive / 0.5A @ 120V AC / 0.25A @ 240V AC resistive AUX. RELAY FAULT 1 rated 2A @ 30V DC resistive / 0.5A @ 120V AC / 0.25A @ 240V AC resistive OPERATING / STORAGE TEMPERATURE ‑10ºC to 50ºC HUMIDITY Max. 85% RH Non‑Condensing PROTECTION Surface Mount꞉ IP30, Recessed Mount꞉ IP65 DIMENSIONS 273 (W) x 404 (H) x 107 (D) mm WEIGHT 1.6 Kg ‑ 7 Kg COLOUR White or Red ORDER CODE GEKKO‑1L 1 LOOP ‑ PSU 2.4A GEKKO‑2L 2 LOOP ‑ PSU 2.4A GEKKO‑3L 3 LOOP ‑ PSU 2.4A GEKKO‑4L 4 LOOP ‑ PSU 2.4A
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 OCTO + Networkable Fire Detection System The OCTO+ Fire Alarm Control Panel is built on the pedigree of the worldwide known JUNO NET. Now featuring a fully peer‑to‑peer, multi‑master networking solution. This new “Chameleon Network” solution enables extreme resilience in very large distributed systems. On a Chameleon Network system, each network NODE+ has, in its internal configuration memory, the whole system information, i.e. in the unlikely event of a communication loss, there is no performance degradation of individual NODE+. The network layout is usually configured in a closed loop or having physical multi‑paths for communications redundancy, which can use either RS422 or Fibre‑Optic mediums. It can also use Ethernet interfaces which can use the existing networking infrastructure. A Chameleon Network can accommodate up to 32 NODE+. Each OCTO+ panel can support from 1 to 4 addressable loops, giving a total of 128 loops in a single system! Naturally, it also supports remote access with our proprietary ODYSSEY Graphics Interface, as well as integration with third party Building Management Systems through a Modbus output. The graphic backlit LCD display accommodates any type of custom characters or graphic symbols, allowing multi‑language support, as well as pictorial and customisable elements. Housed in an aluminum back box with a reversible plastic lid, it comprises a PSU, a Front End Display for visualisation of the C&I equipment status, a NODE+ unit with the loop card fitted and networking interfaces if necessary. For each 4 loops there is space for installing up to 12 A/H 24V DC Sealed Lead Acid backup batteries, more than enough to provide up to 24 H battery supply to the NODE+ and ZEOS associated devices which boast extremely low current consumption. Take into account that all networked panels share the complete system knowledge. On a multi OCTO+ networked panels, as far as the network architecture is concerned, if no human‑machine Interface is needed at a specific location, instead of using
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 a complete OCTO+ panel with display built in, a simple NODE+ panel can be used. By having the same 4 Loops available and housed in the same aluminium back box, without the Front End Display built in the lid, the NODE+ offers the possibility to extend the system, keeping the human interface access only available at specific locations. In addition to this, each NODE+ has provision to communicate with a remote Repeater unit using any of the networking interfaces. The “Cause and Effect” programming as well as customer specific Configurations, can be uploaded to any OCTO+ panel in the network using the CHAMELEON CONNECTOR software tool. This is done by USB connection. Later the updated panel can broadcast the same configuration to all other Chameleon Network panels. KEY FEATURES ● 1 to 4 loops panel ● Up to 250 devices per loop (125 address limit) ● Up to 95 VULCAN 2 (addressable) ultra low current base sounders (32 address limit) ● Supports connection to Repeaters via RS422, Fibre‑Optic or TCP/IP ● Networked system up to 128 loops ● Chameleon Peer‑to‑Peer Advanced Networking Protocol with up to 32 NODE+ ● 32 individually programmable sounder addresses ● Support of Non‑European languages (Mandarin, Arabic, Hindu, Urdu, Farsi, etc.) ● Full Self‑Addressable Devices support ● Built in Fire & Fault relays ● 2 conventional alarm outputs (individually programmable) ● Detection loops monitored for integrity ● 384 fully programmable multi loop zones ● 512 fully programmable sounder groups ● 512 I/O groups ● Event log (rolling, 10000 entries) ● Removable Chassis TECHNICAL SPECIFICATIONS POWER SUPPLY RATING 90V AC to 230V AC @ 65 W PRIMARY SUPPLY 28.5V DC @ 2.4 A (Max.) SECONDARY SUPPLY 21.6 Min. ‑ 27.2V DC (Max.) ‑ Battery charger꞉ 27.5V DC BATTERIES (INTERNAL) 2 x 12V 12 AH (Max.) QUIESCENT CURRENT (NO DEVICES) 80 mA (4 Loop)
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 AUX POWER OUTPUT 28V DC 300 mA LOOPS 1 to 4 loops ‑ Max. 150 mA per loop CONVENTIONAL SOUNDER CIRCUITS 500 mA Max. current drive for both circuits ‑ Fully monitored AUX. RELAYS FIRE 2 rated 2A @ 30V DC resistive / 0.5A @ 120V AC resistive/ 0.25A @ 240V AC resistive AUX. RELAY FAULT 1 rated 2A @ 30V DC resistive / 0.5A @ 120V AC resistive/ 0.25A @ 240V AC resistive OPERATING / STORAGE TEMPERATURE ‑10ºC to 50ºC HUMIDITY Max. 85% RH Non‑Condensing PROTECTION IP30 DIMENSIONS 340 (W) x 370 (H) x 135 (D) mm WEIGHT 7,5 Kg – 10,5 Kg (inc. 2 x 12 AH 12 V bat.) COLOUR White or Red ORDER CODE OCTO+ ‑1L 1 LOOP ‑ PSU 2.4A OCTO+ ‑2L 2 LOOP ‑ PSU 2.4A OCTO+ ‑3L 3 LOOP ‑ PSU 2.4A OCTO+ ‑4L 4 LOOP ‑ PSU 2.4A
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 CHAMELEON REP Chameleon Network Repeater The CHAMELEON REP is the best solution when you need full control of a networked system. In a Chameleon Network, the CHAMELEON REPEATER is used as a “System Repeater”. It works as an addressed networked panel (without loops) and has the ability to process and register (Event‑log) all “system info”. For application connections and diagrams, please refer to our Chameleon Network manual available on our website. The new graphic backlit LCD display can accommodate any type of custom characters or graphic symbols, allowing multi‑language support, as well as pictorial and customisable elements. The CHAMELEON REP is supplied without battery management capability. It is intended to be connected to an external power supply.The Cause and Effect programming of the whole system as well as all customer specific configuration can be downloaded or uploaded using the CHAMELEON CONNECTOR software and later broadcast to other networked panels. MAIN FEATURES ● Networkable panel, compatible with OCTO+ , NODE+ and GEKKO range of panels ● Supports other panels connections via RS422, Fibre‑Optic or TCP/IP ● Event log (rolling, 10000 entries) ● Backlit graphical LCD display of 240x64 pixels ● Programming by integrated keypad or Loader PC software ● Multiple language support (menu selectable) TECHNICAL SPECIFICATIONS PRIMARY SUPPLY 28.5V DC nominal (Max.) QUIESCENT CURRENT 65 mA OPERATING / STORAGE TEMPERATURE ‑10ºC to 50ºC HUMIDITY Max. 85% RH Non‑Condensing PROTECTION Surface Mount꞉ IP30, Recessed Mount꞉ IP65 DIMENSIONS 340 (W) x 370 (H) x 125 (D) mm WEIGHT 760 g COLOUR White or Red ORDER CODE CHAMELEON REP NETWORK SYSTEM REPEATER
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 NFC‑KEY Contactless User Acces MAIN FEATURES TECHNICAL SPECIFICATIONS ORDER CODE CHAMELEON REP NETWORK SYSTEM REPEATER The new GFE‑NFC‑KEY is an easy and fast way to gaincontrol of the panel via theNFC Touchwith accesscard or optionally key fob/tag. The NFC Key is a safe andconvenient way to access your Chameleon fire alarmcontrol panel without the need of entering the password. By means of NFC Interface it is possible to executea pre‑programmed function on any of GFE addressablefire alarm control panels without needing an introduction ofthe access codes. The configurable panel remote inputoptions are꞉ ● Evacuation ● Disable selected detectors ● User access ● Reset ● Disable ● Up to 5 independent access Cards/fobs ● Programmable functions via control panel ● Contactless access ● Small and compact ● Individual access authorization ● Ideal for “first responders” such as Fire Fightersaccess. SUPPLY VOLTAGE SUPPLY CURRENT CONNECTIONS COMPATIBILITY ENCODE / NFC CARD OPERATING TEMPERATURE 20 ‑ 30 VDC Standby (3,9mA) ‑ Card/TAG detection (8mA) 5 Way molex / 2 Way plug for Panel Remote Input OCTO+, GEKKO, G‑One and NODE+ MIFARE RFID 13,56 MHZ 0ºC to 50ºC
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 EN54-21 FIRE ALARM TRANSMITTER
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 EN54‑21 Alarm Contactless User Acces TECHNICAL SPECIFICATIONS ORDER CODE MX03‑D‑TEF‑EN54‑LAN EN54‑21 DUAL PATH ALARM TRANSMITTER MX03‑D‑TEF‑EN54‑LAN (Dual path)The MX03 Fire is an EN54 dual or single path alarm overdrgaer.The alarm dialer is always equipped with 2 e‑SIM connection paths. In addition, the Dual‑path features a LAN connection so you fully meet all Dual‑path requirements.The remote management is easily done via the available portal. ● Evacuation ● Disable selected detectors ● User access ● Reset ● Disable SUPPLY VOLTAGE CURRENT (Standby/Alarm) MOB FREQUENCY COMPATIBILITY ESPA INPUT SIZE TEMP/HUMIDITY 20 ‑ 30 VDC Standby (60mA) ‑ Alarm (200mA) LTE CAT‑M1 700/850/1700/1900/2100 Mhz OCTO+, GEKKO, G‑One and NODE+ RS232 TEF‑SIA‑Protocol 63x90x32mm 0ºC to 50ºC max. 85% Transmitter
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 INTERFACES
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 INT‑RS232 ORDER CODE INT‑RS232 COMMUNICATION INTERFACE Rs232 RS232 COMMUNICATION INTERFACE FOR CHAMELEON NETWORK PANELS The INT‑RS232interface offers a serial communicationsolution for the integration of GFE´s intelligent fire alarm control panels and BMS connection. Serial communication over ESPA, MODBUS and ODYSSEY XLP protocols. ● Full electrical Isolation ● MODBUS compatible ● ESPA 4.4.4 compatible ● ODYSSEY XLP compatible ● 100m maximum distance KEY FEATURES POWER SUPPLY RATING 28V DC SUPPLY CURRENT 5 mA COMPATIBLE PANELS OCTO+ / GEKKO / G‑One / NODE+ MAXIMUM CABLE DISTANCE 100m per connec on OPERATING / STORAGE TEMPERATURE ‑10ºC to 50ºC HUMIDITY Max 95% RH Non‑Condensing DIMENSIONS 100.3 (L) x 35 (W) x 18 (H) mm WEIGHT 20 g TECHNICAL SPECIFICATIONS
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 INT‑RS422‑P2P‑D/S ORDER CODE INT‑RS422‑P2P‑S or D COMMUNICATION INTERFACE RS422 Single or Double Network RS422 INTERFACE FOR CHAMELEON NETWORK PANELS KEY FEATURES TheINT‑RS422‑P2P‑Dinterface allows a double peer‑to‑peerRS422 connection, making it possible to build a closed loop, “daisy‑chained” communication network between GFE's CHAMELEON Panels (G‑One, GEKKO, OCTO+, NODE+ and CHAMELEON REPEATER). TheINT‑RS422‑P2P‑Sinterface allows one single RS422connection. Mainly used for integration to 3rd party BMS systems or for a single extension connection to a CHAMELEON Display. For more detailed information, such as commissioning, network topology options and installation troubleshooting, please refer to theCHAMELEON Network manualor contactour Technical Support team. ● Full electrical Isola on between connec ons ● Independent network paths ● Compa ble only with GFE CHAMELEON Panels ● 1200m maximum cable length per interface. POWER SUPPLY RATING SUPPLY CURRENT RECOMMENDED CABLE MAXIMUM CABLE DISTANCE OPERATING / STORAGE TEMPERATURE HUMIDITY PROTECTION DIMENSIONS WEIGHT COMPATIBILITY ‑ 24VDC (17V to 30V) 14 mA Category 5 cable as defined by the EIA/TIA/ANSI 568 specifica on (<17 pF/ @ 100 ohm) 1200m per connec on ‑10ºC to 50ºC Max 85% RH Non‑Condensing IP30 90 (L) x 40 (H) x 20 (W) mm 33 g All CHAMELEON Panels (G‑One, GEKKO, OCTO+, NODE+, CHAMELEON REP) TECHNICAL SPECIFICATIONS
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 ORDER CODE INT‑FO/RS422‑P2P‑S COMMUNICATION INTERFACE Network KEY FEATURES INT‑MIX‑FO/RS422‑P2P Mixed RS422 and Fiber Optic Interfaces (for CHAMELEON network) The INT‑MIX‑FO/RS422‑P2P interface allows to mix both Fiber Optic (FO) and RS422 in the same installation. Making it possible to build a closed loop, “daisy‑chained” communication network between GFE's CHAMELEON Panels (GEKKO, OCTO+, NODE+ and CHAMELEON REPEATER). For more detailed information, such as commissioning, network topology options and installation troubleshooting, please refer to the CHAMELEON Network manual or contact our Technical Support team. ● Full electrical Isolation between connections ● Compatible with GFE CHAMELEON Panels ● 1200m maximum cable length for RS422 ● 2500m maximum cable length for Fiber Optic. POWER SUPPLY SUPPLY CURRENT RECOMMENDED CABLE RS422 MAXIMUM CABLE DISTANCE (Rs422) RECOM. CABLE/CONNECTOR (FO) MAXIMUM CABLE DISTANCE (FO) OPERATING/ STORAGE TEMPERATURE HUMIDITY PROTECTION DIMENSIONS WEIGHT COMPATIBILITY TECHNICAL SPECIFICATIONS 24V DC (17V to 30V DC) 15 mA CAT5E (<17 pF/ft @ 100 ohm) 1200m per connection Multi‑mode 62.5/125 μm with ST Connector 2500m per connection ‑10ºC to 50ºC Max 85% RH Non‑Condensing IP30 90 (L) x 40 (H) x 20 (W) mm 33 g CHAMELEON Panels (GEKKO, OCTO+, NODE+, CHAMELEON‑REP)
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 ORDER CODE INT‑FO‑P2P‑D/S COMMUNICATION INTERFACE Network KEY FEATURES INT‑FO‑P2P‑D/S Fiber Optic Interfaces (for CHAMELEON network) The INT‑FO‑P2P‑D interface allows double peer‑to‑peer Fiber Optic connection, making possible to build a closed loop, “daisy‑chained” communication network between GFE's CHAMELEON Panels (GEKKO, OCTO+, NODE+ and CHAMELEON REPEATER). The INT‑FO‑P2P‑S interface allows one single Fiber Optic connection. Mainly used for integration to 3rd party BMS systems or for a single extension connection to a CHAMELEON Display. For more detailed information, such as commissioning, network topology 1 options and installation troubleshooting, please refer to the CHAMELEON Network manual or contact our Technical Support team. ● Full electrical Isolation between connections ● ndependent network paths ● Compatible only with GFE CHAMELEON Panels ● 2500m maximum cable length between interfaces. TECHNICAL SPECIFICATIONS POWER SUPPLY RATING 24V DC (17V to 30V DC) SUPPLY CURRENT 15 mA RECOMMENDED CABLE / CONNECTOR Multi‑mode 62.5/125 µm with ST Connector MAXIMUM CABLE DISTANCE 2500m per connection OPERATING/ STORAGE TEMPERATURE ‑10ºC to 50ºC Max 85% RH Non‑Condensing PROTECTION HUMIDITY IP30 DIMENSIONS 90 (L) x 40 (H) x 20 (W) mm WEIGHT 33 g COMPATIBILITY All CHAMELEON Panels (GEKKO, OCTO+, NODE+,
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 DETECTORS
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 ZEOS‑AD Analogue Addressable Fire Detectors The ZEOS‑AD series of Analogue Addressable Detectors have been designed to be fully compatible with the Global Fire Equipment range of intelligent control panels, JUNIOR and JUNO NET. The ZEOS detector range, in conjunction with JUNIOR and JUNO NET panels, can accommodate several Alarm thresholds and timed options in combined smoke and heat detectors variants. Certified to EN54‑5 and EN54‑7 the ZEOS‑AD series detectors are available in optical, heat and combined smoke/heat detector versions. Optionally they can be fitted with a short‑circuit loop isolator. Key Features Dual LEDs for 360º visibility Advanced detection and communication protocols Easy installation and maintenance Sleek low‑profile housing Durable sensor head, no need for replacement Programmable LED ouput SMD circuit board design. High quality and reliability guaranteed ORDER CODE TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE CURRENT - QUIESCENT / SURGE CURRENT - DEVICE IN ALARM SENSITIVITY CABLE SIZE RESET/START-UP TIMES SMOKE SENSITIVITY SETTINGS HEAT ALARM SETPOINTS MULTISENSOR MODES COLOUR / CASE MATERIAL NORMAL / TRANSIENT OPERATION TEMPERATURE MAX. HUMIDITY DIMENSIONS WEIGHT Loop Powered 17-30 V DC 450 uA max. 4 mA - Alarm LED illuminated According to EN54-5 and EN54-7 0.5-2.5 mm² 20 seconds max. Low / Normal (default) / High 55 C / 65 C (default) / 75 C / 85 C Heat / Smoke / Combined (default) White / ABS 0ºC to 50ºC / -10ºC to 85ºC 95% RH Non‑Condensing 100 (D) x 50 (H) mm inc. base 92 g (without base) & 144 g (inc. base) ZEOS-AD-S ZEOS-AD-H ZEOS-AD-SHI ANALOGUE ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR ANALOGUE ADDRESSABLE TEMPERATURE/HEAT DETECTOR ANALOGUE ADDRESSABLE COMBINED SMOKE & HEAT DETECTOR WITH ISOLATOR 1328-CPR-0521 1328-CPR-0520 1328-CPR-0492
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 ZEOS BASE Standard Detector Base ZEOS‑BASE design and materials guarantees a proper electrical contact with detector head which is key to ensure a stable system. Mounting Zeos Base to uneven ceilings has been made easier because of narrow contact points. Deep Detector Base This mounting option enables external wiring conduits in locations like car parking's, warehouses, etc. ORDER CODE TECHNICAL SPECIFICATIONS DIMENSIONS COLOUR / CASE MATERIAL ZEOS-BASE ZEOS‑DEEP‑BASE Standard꞉ 100 (D) x 10 (H) mm / Deep꞉ 100 (D) x 30 (H) mm White / ABS STANDARD DETECTOR BASE DEEP DETECTOR BASE
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 GFE‑BASE ZEOS detector base w/ buzzer or relay Accommodated inside our deep base, GFE‑BASE‑BUZ has a built‑in piezo buzzer and it’s an option for local alarm signalling in places like offices, hotel rooms and class rooms at a lower cost than a VULCAN 2 base sounder. GFE‑BASE‑REL has a relay which is a very practical solution for ventilation damper activation together with our detector housing. Both options are loop powered making them a viable and low cost solution for localized audible notification and external activation. ORDER CODE TECHNICAL SPECIFICATIONS SUPPLY CURRENT RELAY RATING BUZZER OUTPUT DIMENSIONS COLOUR / CASE MATERIAL GFE-BASE-BUZ GFE‑BASE‑REL Loop powered 21 mA 30 V DC/ 2A 75 dB 100 (D) x 30 (H) mm White / ABS ZEOS DETECTOR BASE W/ BUZZER ZEOS DETECTOR BASE W/ RELAY
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 ORDER CODE TECHNICAL SPECIFICATIONS ADDRESSABLE FLASHING REMOTE INDICATOR GFE-REM-IND-A GFE‑REM‑IND‑A Addressable Flashing Remote Indicator The GFE‑REM‑IND‑A is designed to provide discreet remote indication and is controlled by the addressable control panel, whilst providing the ability to monitor multiple sensors within a zone thereby minimising wiring requirements. The GFE‑REM‑IND‑A is compatible with any of GFE’s analogue addressable panels. The unit can be activated either by any of GFE’s analogue addressable fire detectors sharing the same loop address or alternatively by the panel’s cause and effect programming and in this particular mode of operation, multiple detectors can be used to activate the device. The GFE‑REM‑IND‑A is supplied complete with a back box, enabling the device to be surface mounted. It will also fit on to a standard single gang box. SUPPLY VOLTAGE LOOP CURRENT ‑ Remote Indicator LOOP CURRENT ‑ IO MAX. CABLE SIZE MAX. HUMIDITY OPERATING TEMPERATURE DIMENSIONS WEIGHT Loop Powered - 20 V to 30 V DC 0.12 mA (Quiescent) ‑ 2.5 mA (LED ON) 0.625 mA (Quiescent) ‑ 2.5 mA (LED ON) 2.5 mm² 95% RH Non-Condensing -10ºC to 50ºC 86 (L) x 86 (W) x 25 (H) mm 60 g Boxed
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 GFE‑REM‑IND‑C Conventional Flashing Remote Indicator This remote indicator can be used with any fire alarm detector, be it of the conventional types, to indicate remotely the activation of the relevant detection device. Its main characteristics are the high visibility due to the flashing of 2 high efficiency LEDs and the wide operating voltage range (3.3 V to 10 V DC) with a maximum 7 mA current consumption. The connections of this device are non‑polarised. ORDER CODE TECHNICAL SPECIFICATIONS CONVENTIONAL FLASHING REMOTE INDICATOR GFE-REM-IND-C SUPPLY VOLTAGE SUPPLY CURRENT MAX. CABLE SIZE MAX. HUMIDITY OPERATING TEMPERATURE DIMENSIONS WEIGHT 3.3 V to 10 V DC 7 mA max. 2.5 mm² 95% RH Non-Condensing -10ºC to 50ºC 86 (L) x 86 (W) x 25 (H) mm 50.1 g = module 4,8 g + box 45,3 g
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 UG‑4 Duct Smoke Sampling System UG‑4 duct housing is a simple and effective solution to monitor smoke presence in ventilation ducts or other HVAC conducts. Based in Venturi effect, air sampling it's naturally aspirated because of aerodynamic shape of sampling tube. The venturi tube conducts the air from the duct to the detector housing, which is fitted to the outside of the duct, where a smoke detector detects potential fire particles in the air. UG‑4 should be installed according to air flow direction in the duct but it can be installed on any side of the duct. We recommend that the UG‑4 is mounted at an equal distance from heating, cooling or humidity devices. A distance of 3 times the duct diameter should be left before a damper, filter or change of the duct direction and 5 times the diameter after these devices to assure the presence of laminar flow. For detailed information about installation, download manual available in our website. TECHNICAL SPECIFICATIONS ORDER CODE DUCT HOUSING VR-0.6M VR-1.5M VR-2.8M DUCT SMOKE SAMPLING SYSTEM VENTURI PIPE 0.6 METER FOR UG-4 VENTURI PIPE 1.5 METER FOR UG-4 VENTURI PIPE 2.8 METER FOR UG-4 MATERIAL WEIGHT꞉ HOUSING WEIGHT꞉ VENTURI PIPE IMENSIONS꞉ HOUSING DIMENSIONS꞉ VENTURI PIPE ABS / Aluminum 708 g 0.6 m - 377 g / 1,5 m - 950 g / 2,8 m - 1760 g 180 (W) x 235 (H) x 183 (D) mm 23 (W) x 35 (D) mm
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 FIRE BEAM Blue/Xtra Reflective Optical Beam Smoke Detector FIRE BEAM is the optimal solution to protect large areas with ceiling height greater than 4 meters. A motorized beam head will self‑align itself to the centre of the reflector when commissioning and will automatically keep alignment when building movement occurs which will prevent unwanted false alarms. Additionally, the ground level controller facilitates any change or adjustment. Its low current consumption enables seamless integration with addressable systems via an Input or ZMU modules. Another relevant feature is related with its environmental protection that makes FIRE BEAM a suitable solution for harsh industrial applications, in situations where condensation may occur, filters with special coating widens the scope of usage. Key Features Dual LEDs for 360º visibility Low power IP65 environmental protection Ground level commissioning Multi language interface Motorized beam head 1500 m² maximum coverage TECHNICAL SPECIFICATIONS ORDER CODE ELECTRICAL SUPPLY VOLTAGE SUPPLY CURRENT STATUS INDICATORS NORMAL FAULT ALARM ENVIRONMENTAL TEMPERATURE HUMIDITY IP RATING MECHANICAL BEAM HEAD 7‑70M CONTROLLER 70KIT140 MID-RANGE REFLECTOR 140KIT160 LONG RANGE REFLECTOR ADAPTER 10.2 to 40V DC 3 mA (quiescent; alarm; fault) Green LED’s Flashing / Controller Message Yellow LED’s Flashing / Change over relay (2A@30VDC)/ Controller Message Red LED’s Flashing / Change over relay (2A@30VDC)/ Controller Message -10°C to +55°C 10 to 95% RH Non-condensing IP65 when suitably mounted and terminated 180 (H) x 155 (W) x 137 (D) mm / Weight 1.1 Kg 185 (H) x 120 (W) x 62 (D) mm / Weight 0.55 Kg 293 (H) x 293 (W) x 5 (D) mm / Weight 0.8 Kg 394 (H) x 394 (W) x 5 (D) mm / Weight 1.8 Kg 270 (H) x 250 (W) x 5 (D) mm / Weight 0.6 Kg (mounts the Beam Head onto unistrut) FIRE BEAM-BLUE/XTRA 40KIT80 80KIT100 ADAPTER ANTI-FOG FIRE BEAM 40KIT80-AF 80KIT100-AF WINDOW-AF REF-AF FOGKIT BASIC FIRE BEAM INCL. CONTROLLER + 1 REFLECTOR COVERS DISTANCE OF 5-40 METERS MID RANGE EXTENSION KIT 40-80 M LONG RANGE EXTENSION KIT 80-100 M HEAD INTERFACE ADAPTER TO MOUNT TO UNISTRUT ANTI FOG FIRE BEAM ANTI FOG MID RANGE EXTENSION KIT 40-80 M ANTI FOG LONG RANGE EXTENSION KIT 80-100 M ANTI FOG WINDOW SINGLE ANTI FOG REFLECTOR ANTI FOG WINDOW FOR HEAD AND SINGLE ANTI FOG REFLECTOR
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 MANUAL CALL POINTS
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE CURRENT - QUIESCENT CURRENT - DEVICE IN ALARM CABLE SIZE MAX. RECOMMENDED PER LOOP COLOUR / CASE MATERIAL PROTECTION OPERATING TEMPERATURE MAX. HUMIDITY DIMENSIONS WEIGHT Loop Powered 20-30 V DC 500 uA - 650 uA for GFE-MCPE‑AI 3.1 mA - Yellow LED ON only applies to GFE-MCPE‑AI 0.5-2.5 mm² 30 GFE-MCPE‑A or GFE-MCPE‑AI Red / ABS & Clear/ PC ‑ Flame Retardant 94 V0 IP24D ‑10ºC to 55ºC 95% RH Non‑Condensing 92.6 (W) x 92.6 (H) x 60.1 (D) mm 152 g ORDER CODE GFE‑MCPE‑A Addressable Manual Call Point The GFE‑MCPE‑A is an Analogue Addressable Manual Call Point, designed and manufactured to comply with EN54‑ 11, compatible with all GFE Addressable Control panels. With its enhanced communications mechanism the typical response time, when in alarm, is approximately one second, depending on the number of call points connected to the device loop. There is also a version incorporating a Loop Isolator. A bi‑colour LED flashes Green when the unit is interrogated by the control panel and is illuminated Red when in Alarm. The command to illuminate the Red LED is emitted by the control panel in response to activation of the individual call point thus confirming that the Alarm signal has been received at the control panel. The individual address, up to 125, of each call point is set via an eight way DIL switch. The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and reduces malicious activations as two actions are required in order to activate the device. This unit can be both surface and flush mounted and it can be easily reset using the supplied key after activation. ADDRESSABLE MANUAL CALL POINT ADDRESSABLE MANUAL CALL POINT WITH LOOP ISOLATOR GFE-MCPE‑A GFE-MCPE‑AI 1328-CPR-0374 1328‑CPR‑0375
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 ORDER CODE TECHNICAL SPECIFICATIONS GFE‑MCPE‑AI‑IP67 Addressable Manual Call Point Outdoor Use‑IP67 The GFE‑MCPE‑AI‑IP67 is an Analogue Addressable Manual Call Point, designed and manufactured to comply with EN54‑11, compatible with all GFE Addressable Control panels specially recommended for outdoor use. With its enhanced communications mechanism, the typical response time, when in alarm, is approximately one second, depending on the number of call points connected to the device loop. The individual address, up to 125, of each call point is set via an eight way DIL switch. Each unit is supplied, as standard, with a loop short circuit isolator. A bi‑colour LED flashes Green when the unit is interrogated by the control panel and is illuminated Red when in alarm. The GFE‑MCPE‑AI‑IP67 has been designed to deal with today’s difficult and harsh environments. It is a unique fire alarm manual call point that mimics the feel of breaking glass whilst offering the user the benefits and safety advantages of a glass‑free resettable operating element. Once activated a warning flag drops in to view easily identifying the call point that has been operated. A key can then reset the unit. The GFE‑MCPE‑AI‑IP67 provides an ideal solution for GFE’s addressable fire alarm systems. Ideal for all outdoor applications such as oil rigs, ships, factories as well as wash down areas that are sensitive to broken glass. GFE-MCPE-AI-IP67 IP67 RATED ADDRESSABLE CALL POINT SUPPLY VOLTAGE CURRENT ‑ QUIESCENT CURRENT ‑ DEVICE IN ALARM MAX. CABLE SIZE MAX. RECOMMENDED PER LOOP COLOUR / CASE MATERIAL PROTECTION OPER. TEMPERATURE / MAX. HUMIDITY DIMENSIONS Loop Powered 20-30 V DC 500 uA 3.5 mA - Alarm LED illuminated 0.5‑2.5 mm² 30 Red / ABS & Clear/ Polycarbonate ‑ Flame Retardant 94 V0 IP67 ‑10ºC to 50ºC / 95% RH Non‑Condensing 111.9 (H) x 111.9 (W) x 81.3 (D) mm 1328-CPR-0376
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 SOUNDERS & BEACONS
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE LOOP CURRENT - QUIESCENT LOOP CURRENT - SOUNDER/ BEACON ACTIVE MAXIMUM SOUNDER OUTPUT MAX. CABLE SIZE OPERATING TEMPERATURE MAX. HUMIDITY COLOUR / CASE MATERIAL PROTECTION CATEGORY DIMENSIONS WEIGHT Loop꞉ 20 V to 30 V DC 0.5 mA 10 mA ‑ 280 mW @ 28 V DC inc. isolator 100 dB (@ 1 meter ‑ 30 V DC) 2.5 mm² ‑10ºC to 55ºC 95% RH Non-Condensing Red or White / ABS and PC IP21C ‑ Type A ‑ Indoor use 110 (D) x 85 (H) mm inc. base 254 g ‑ inc. mounting base ORDER CODE VALKYRIE ASI Addressable Wall Mount Sounder/ Beacon The VALKYRIE AS is a Wall Mounted Addressable Sounder/ Beacon with low power consumption. Up to 32 individually addressed sounders can be installed per loop occupying address 94 to 125. The address is set using switches 1 to 5 of the 8 way DIL switch. Four different tones are available and selected using DIL switches 6 and 7. When individual address reporting is not required, VALKYRIE AS can be configured as a Shadow Sounder. In this case sounders do not occupy an address in the loop thus freeing up addresses for more detection devices. Shadow sounders do not report back to the control panel so their presence on the loop is not monitored. Shadow sounders draw current from the loop (10 mA in alarm) and must be included in loop load calculations. ALKYRIE ASI VALKYRIE ASBI ADDRESSABLE WALL SOUNDER WITH ISOLATOR ADDRESSABLE WALL SOUNDER/ BEACON WITH ISOLATOR 1328-CPR-0286 1328-CPR-0286
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 VALKYRIE ASI IP65 Addressable Wall Mount Sounder/ Beacon Outdoor Use‑IP65 The VALKYRIE AS IP65 is a Wall Mounted Addressable Sounder/ Beacon with low power consumption. It is specifically designed to be used outdoors. Up to 32 individually addressed sounders can be installed per loop occupying address 94 to 125. The address is set using switches 1 to 5 of the 8 way DIL switch. Four different tones are available and selected using DIL switches 6 and 7. When individual address reporting is not required, VALKYRIE AS IP65 can be configured as a Shadow Sounder. In this case sounders do not occupy an address in the loop thus freeing up addresses for more detection devices. Shadow sounders do not report back to the control panel so their presence on the loop is not monitored. Shadow sounders draw current from the loop (10 mA in alarm) and must be included in loop load calculations. TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE LOOP CURRENT - QUIESCENT LOOP CURRENT - SOUNDER/ BEACON ACTIVE MAXIMUM SOUNDER OUTPUT MAX. CABLE SIZE OPERATING TEMPERATURE MAX. HUMIDITY COLOUR / CASE MATERIAL PROTECTION CATEGORY DIMENSIONS WEIGHT Loop꞉ 20 V to 30 V DC 0.5 mA 10 mA ‑ 280 mW @ 28 V DC inc. isolator 108 dB (@ 1 meter ‑ 30 V DC) 2.5 mm² ‑25ºC to 70ºC 95% RH Non-Condensing Red / ABS and PC IP65 ‑ Type B ‑ Outdoor use 112 (D) x 110 (H) mm inc. base 315 g / 350 g ‑ including packaging ORDER CODE VALKYRIE ASI IP65 VALKYRIE ASBI IP65 ADDRESSABLE WALL SOUNDER WITH ISOLATOR ‑ IP65 RATED ADDRESSABLE WALL SOUNDER/ BEACON WITH ISOLATOR ‑ IP65 RATED 1328-CPR-0299 1328‑CPR‑0299
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 VALKYRIE AB Addressable Beacon The VALKYRIE AB is a Wall Mounted Addressable Beacon with low power consumption. Up to 32 individually addressed beacons can be installed per loop occupying address 94 to 125. The address is set using switches 1 to 5 of the 8 way DIL switch. When individual address reporting is not required, VALKYRIE AB can be configured as a Shadow Beacon. In this case sounders do not occupy an address in the loop thus freeing up addresses for more detection devices. Shadow beacons do not report back to the control panel so their presence on the loop is not monitored. Shadow beacons draw current from the loop (3 mA in alarm) and must be included in loop load calculations. These units are produced using the latest high intensity LED technology and use extremely low levels of current consumption providing a highly visible flash. TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE LOOP CURRENT ‑ QUIESCENT LOOP CURRENT - ALARM BEACON MAX. CABLE SIZE OPERATING TEMPERATURE MAX. HUMIDITY COLOUR / CASE MATERIAL PROTECTION DIMENSIONS WEIGHT Loop꞉ 20 V to 30 V DC 0.5 mA 3 mA Max. 2.5 mm² ‑10ºC to 55ºC 95% RH Non-Condensing Red or White / ABS IP44 ‑ Type A ‑ Indoor use 110 (D) x 49.5 (H) mm 150 g ‑ inc. beacon / 180 g ‑ inc. packaging ORDER CODE VALKYRIE AB VALKYRIE ABI ADDRESSABLE BEACON ADDRESSABLE BEACON WITH ISOLATOR
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 VALKYRIE CB Conventional Beacon The VALKYRIE CB is a Conventional Beacon produced using the latest high intensity LED technology and use extremely low levels of current consumption providing a highly visible flash. It can be supplied in either white or red colour. TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE LOOP CURRENT ‑ QUIESCENT LOOP CURRENT - ALARM BEACON MAX. CABLE SIZE OPERATING TEMPERATURE MAX. HUMIDITY COLOUR / CASE MATERIAL PROTECTION DIMENSIONS WEIGHT Loop꞉ 20 V to 30 V DC 0.5 mA 3 mA Max. 2.5 mm² ‑10ºC to 55ºC 95% RH Non-Condensing Red or White / ABS IP44 110 (D) x 49.5 (H) mm 150 g ‑ inc. beacon / 180 g ‑ inc. packaging ORDER CODE VALKYRIE CB CONVENTIONAL BEACON
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 VALKYRIE ABI IP65 Addressable Wall Mounted Beacon w/ Isolator Outdoor Use‑IP65 The VALKYRIE ABI IP65 is a Wall Mounted Addressable Beacon with Isolator and low power consumption. It is specifically designed to be used outdoors. Up to 32 individually addressed beacons can be installed per loop occupying address 94 to 125. The address is set using switches 1 to 5 of the 8 way DIL switch. When individual address reporting is not required, VALKYRIE ABI IP65 can be configured as a Shadow Beacon. In this case sounders do not occupy an address in the loop thus freeing up addresses for more detection devices. Shadow beacons do not report back to the control panel so their presence on the loop is not monitored. Shadow beacons draw current from the loop (3 mA in alarm) and must be included in loop load calculations. These units are produced using the latest high intensity LED technology and use extremely low levels of current consumption providing a highly visible flash. TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE LOOP CURRENT ‑ QUIESCENT LOOP CURRENT - ALARM BEACON MAX. CABLE SIZE OPERATING TEMPERATURE MAX. HUMIDITY COLOUR / CASE MATERIAL PROTECTION DIMENSIONS WEIGHT Loop꞉ 20 V to 30 V DC 0.5 mA 3 mA Max. 2.5 mm² ‑25ºC to 70ºC 95% RH Non-Condensing Red / ABS IP65 ‑ Type B ‑ Outdoor use 112 (D) x 82 (H) mm 205 g inc. sounder base / 240 g ‑ inc. packaging ORDER CODE VALKYRIE ABI IP65 ADDRESSABLE WALL MOUNTED BEACON WITH ISOLATOR ‑ IP65 RATED
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 VALKYRIE CB IP65 Conventional Wall Mounted Beacon Outdoor Use‑IP65 The VALKYRIE CB IP65 is a Wall Mounted Conventional Beacon produced using the latest high intensity LED technology and use extremely low levels of current consumption providing a highly visible flash. It is specifically designed to be used outdoors. TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE CURRENT ‑ QUIESCENT CURRENT - ALARM BEACON MAX. CABLE SIZE OPERATING TEMPERATURE MAX. HUMIDITY COLOUR / CASE MATERIAL PROTECTION DIMENSIONS WEIGHT 20 V to 30 V DC 0.5 mA 3 mA Max. 2.5 mm² ‑25ºC to 70ºC 95% RH Non-Condensing Red / ABS IP65 ‑ Type B ‑ Outdoor use 112 (D) x 82 (H) mm 205 g inc. sounder base / 240 g ‑ inc. packaging ORDER CODE VALKYRIE CB IP65 CONVENTIONAL WALL MOUNTED BEACON ‑ IP65 RATED
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE LOOP CURRENT - QUIESCENT LOOP CURRENT ‑ BEACON MAXIMUM SOUNDER OUTPUT MAX. CABLE SIZE OPERATING TEMPERATURE MAX. HUMIDITY COLOUR / CASE MATERIAL DIMENSIONS / WEIGHT ORDER CODE VULCAN 2 A(SB)I Addressable Low‑Profile Sounder/ Beacon The addressable VULCAN 2 A is available as an Addressable Sounder/ Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Sounder/ Beacon devices can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip‑switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A. Shadow Sounder/ Beacon꞉ A Shadow Sounder/ Beacon does not have an individual address thus freeing up addresses for more detection devices. Shadow Sounder/ Beacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Sounder/ Beacon꞉ When the VULCAN 2 A is configured as an Auxiliary device, it shares the same address as the detector with which it is co‑located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated. If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Sounder/ Beacons is 63 and they can be allocated between address 1 and 63. Loop Powered - 20 V to 30 V DC 0.5 mA Beacon 2.5 mA - Beacon with isolator 2.7 mA 97 dB (@ 1 meter - 30 V DC) 2.5 mm² -10ºC to 55ºC 95% RH Non-Condensing White or Red / ABS - Transparent PC 100 (D) x 50 (H) mm / 144 g inc. base VULCAN 2 ASI VULCAN 2 ABI VULCAN 2 ASBI VULCAN 2 L VULCAN 2 LT ADDRESSABLE BASE SOUNDER WITH ISOLATOR ADDRESSABLE BASE BEACON WITH ISOLATOR ADDRESSABLE BASE SOUNDER WITH BEACON WITH ISOLATOR OPAQUE LID FOR VULCAN 2 TRANSPARENT LID FOR VULCAN 2 1328-CPR-0288 1328‑CPR‑0288 1328‑CPR‑0288
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 MODULES
tef.eu ‑ globalfire.pt Manufacturers of Fire Detection Equipment TEF‑GFE ‑ 2023 LSC‑ISO Loop Sounder Control Module (with 1 A monitored output) The LSC‑ISO Module is a fully monitored interface which is used to connect a line of conventional sounders to the GFE’s range of Addressable Fire Detection Control Panels via the detection loop. The Green LED will pulse every time the unit is polled by the panel. Three LEDs are provided to indicate module status. The Yellow LED will be ON whenever there is a fault condition in the module and finally the Red LED will be ON when there is an alarm condition in the conventional zone. The module requires an external 24V DC power supply and can supply up to 1A at the sounder output which is monitored for both open and short circuit faults. A 10 K ohm end of line resistor is connected to the last sounder to provide line monitoring. The LSC‑ISO uses the Global Fire proprietary sounder control protocol and therefore is only compatible with GFE’s range of addressable control panels. The output can be programmed as pulsed or continuous. A maximum of 32 LSC‑ISO can be connected to each Loop using address numbers 94 to 125 inclusive. Also available complete with housing. Address setting is via switches 1 to 5 of the 6 way DIL switch where all off represents address 94. TECHNICAL SPECIFICATIONS ORDER CODE LSC-ISO LOOP SOUNDER CONTROL UNIT 17 V to 30 V DC 1.0 mA (Quiescent or OC/ SC FAULT) - 1.65 mA O/P active 1.2 mA Quiescent - 1 Amp maximum for sounders 2.5 mm² -10ºC to 50ºC 95% RH Non-Condensing White or Red / ABS 100 (D) x 48 (H) mm 24 g 155 g SUPPLY VOLTAGE LOOP CURRENT EXT. SUPPLY CURRENT @ 24 V DC MAX. CABLE SIZE OPERATING TEMPERATURE MAX. HUMIDITY ENCLOSURE / MATERIAL DIMENSIONS WEIGHT - MODULE WEIGHT - BOXED
www.tef.euRkJQdWJsaXNoZXIy MTY2MjU=